ENGINE CONTROL AND MONITORING |
|
|
|
Home > Legacy: Blow-by Meters > BB100 |
|
|
| Description: |
 | | 1 |
The BB100 blow-by meter has all of the features of the BB400MR except that the BB100 is a single-range meter measuring from 4 to 150 liters/min (LPM). This range is suitable for blow-by measurement of most passenger car and light-duty truck engines.
|
| Specifications: |
| Range: | 4 to 150 liters/min (LPM), 0.15 to 5.4 ft3/min (CFM) | | Accuracy: | 1% of reading or 1 LPM | | Pressure Drop: | 0.5" H2O at 20% of maximum flow | | Temperature Range: | 0 to 250 deg C (flow), -20 to 85 deg C (electronics) | | Analog Output: | 0 to 5 V, programmable for flowrate or total flow, range, and averaging | | RS-232: | Yes, bidirectional. | | Material Exposed to Blow-by: | Anodized aluminum, Stainless steel, Teflon | | Power: | 11 to 28 VDC, AC/DC adapter supplied | | Size: | 4" x 14.5" x 5.25", 102 mm x 368 mm x 133 mm (W x H x D) | | Weight: | 5.5 lbs., 2.5 kg. |
|
The complete kit includes the following parts:
| Item | Description | P/N | Qty | Photo |
|---|
| 1. | BB100 Meter | 100A-1 | 1 |  | | 2. | Mounting Bracket and Hardware | 100A-2 | 1 |  | | 3. | Power Cord, 10 ft. | 100A-3 | 1 |  | | 4. | 120VAC AC/DC Adapter | 100A-4 | 1 |  | | 5. | Plastic Connector and Terminals for Power Input (same connector as on 100A-4) | 100A-5 | 1 |  | | 6. | Instruction Manual | 100A-7 | 1 |  |
|
|